  • 1
  • 2

Model Number : MLF

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Electromagnetic Flow Meter

Pipeline Diameter : DN100

Accuracy : Up to 0.2%

Flange : GB/ANSI/JIS/BS/Others

Pressure Rate : 0.6MPa-4.0MPa

IP Class : IP65

Contact Now

Magnetic Battery Operated Flow Meter for Water and Wastewater

1. Introduction

The MLF electromagnetic flow meter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water, raw water conductivity of about 100 to 500μs/cm), can also be used to measure acids, alkali, brine, pulp or pulp and other media. However, these media must not contain large amounts of magnetic substances and bubbles.

MLF electromagnetic flow meter is an instrument for measuring liquid flow. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textiles, food, urban management, water plants and other industries flow metering.

2. Features

MLF electromagnetic flowmeter is explosion-proof design.

The function of low conductivity measurement.

There are 9 language options to meet the needs of different customers.

There are self-regulating functions and self-checking.

Different outputs are optional: Hart, RS485,Profibus, 4-20mA, frequency, pulse.

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Dimensional Sketches

a. Dimension of Converter

Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter

Divided Type

Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter

Integrated Type

Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter

Battery Powered Type

b. Dimension of Sensor

Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

5. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

6. Instrument Testing & Maintenance

Electromagnetic flowmeter has self-diagnosis function. In addition to power supply and hardware circuit faults, the system also alarms other faults in general use. These messages are prompted in the bottom right corner of the screen.

Maintenance and repair

A) The sensor installation site shall meet the requirements of Section 4, and please keep the shell clean;

B) The transmitter shall be placed in a clean, ventilated and dry place;

C) The instrument shall be inspected every two years. For high-precision users, the instrument shall be submitted for review.

Transportation and storage

A) The instruments must be packed well before transportation and handled with care during loading and unloading.

B) The storage site must be dry and ventilated to avoid corrosive gas, and the ambient temperature should not be too low or too high;

C) Storage time should not exceed three years.

3. Open the box for inspection

A) The package must not be opened with a heavy hammer. Care must be taken not to damage the instrument

B) Carefully check the contents according to the packing list.


Product Tags:

Wastewater Magnetic Flow Meter

      

IP65 Magnetic Flow Meter

      

DN100 Magnetic Flow Meter

      
Quality Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter for sale

Anti Alkali IP65 DN100 Wastewater Magnetic Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0